Description
DeZorel Power Conditioner Audio Reference Second generation Line Filter 120Volts 3 station Used, working Perfectly Technical Specifications All models, except where stated otherwise Device Passive high performance power line filter. Electrical construction Custom aluminium case housing the filter, fully grounded and protected. Double Faraday cage concept, using parallel filters for increased power handling and total isolation of connected devices after filtering. Mechanical Construction Frame beam case construction, using custom high pressure extruded and anodized profiled beams. Insets of painted aluminium plates. High torque screws. Connections IEC Input via fused IEC socket. Power handling VAC, 50/60 Hz - 10 amperes per filter, kva per high power filter VAC, 50/60 Hz 6 amperes per filter, kva per low power filter Insertion loss Approximately 1 V (typically 0.7 V), VAC 50/60 Hz Energy storage Approximately 0.04 joules Fuses VAC, 50/60 Hz, Main Fuse (back of device) 10 A slow blow VAC, 50/60 Hz, high power filter (inside) 10 A slow blow VAC, 50/60 Hz, low power filter (inside) 6 A slow blow Note: The fuses have deliberately been selected to be slow blow. Therefore, transient switch-on surges are well accommodated for without any adverse effects.Filter section overload margin Minimum 200% over nominal threshold before saturation (all protection short circuited). Typically around 300% above nominal power handling before onset of saturation. Minimum guaranteed specifications All above figures were measured at 220 VAC, 50 Hz, at full rated power handling, i.e. at 9.9 amperes (0.1 A below nominal triggering point). DeZorel series: Frequency Min. guaranteed Typical 6 khz - 12 db - 15 db 12 khz - 15 db - 18 db 24 khz - 33 db - 37 db 48 khz - 38 db - 42 db 96 khz - 43 db - 48 db 192 khz - 48 db - 54 db 384 khz - 53 db - 59 db 600+ khz - 62 db - 68 db DeZorel Monocrystal series: Frequency Min. guaranteed Typical 6 khz - 15 db - 18 db 12 khz - 18 db - 22 db 24 khz - 36 db - 43 db 48 khz - 42 db - 49 db 96 khz - 48 db - 56 db 192 khz - 54 db - 62 db 384 khz - 60 db - 68 db 600+ khz - 70 db - 78 db Crossfeed, filter to filter Better than -120 db (1 million to one), one device to any other RF breakthrough Below any publically available known standard, in -> out = out -> in 12Operating temperature degrees centigrade ( degrees Fahrenheit) ambient Generated temperature Maximum +3 deg. Centigrade (+6 deg. Fahrenheit) at maximum ambient and full load Operating humidity % air humidity (receptacle limited) Operating altitude ,000 m (0...33,500 ft) relative to sea level. Internal wiring Silicon insulated OFC multi strand wire on standard models, Neotech Monocrystal OFC wire on Monocrystal series models. IEC soket power input Current rating 16 amps per UR, 10 amps per CE and IEC standards, multiple safety certificates on socket. Type 321 male. Tolerances 0.1% symmetry deviation or better. Operating mode True balanced, fully floating mode. Completely symmetrical operation. Do not require grounding for full effect operation. DeZorel by DDM Elektro d.o.o. Ruzveltova Belgrade Serbia
Live search